Accuracy of depth indication: <4 in: ±0.5 in;>4 in: ±15 %
Data memory: Aprox. 20 scans
Data memory (scanner): Aprox. 20 scans
Features
Provides a real-time view of the inside of concrete structures and
generates true images automatically, for direct on-site evaluation of
scan data by the user - no expert skills required
Features two scan modes for specific applications: Quickscan detection
and Imagescan for 2-D data visualization with top view and
cross-sectional views
Compact all-in-one hand-held scanner offering easy, user-friendly
operation, quick start-up for speed of use plus unmatched data
visualization
Displays a top view of the scan for easy mapping of the objects
detected plus cross sections in both directions for easy identification
of multiple layers in concrete structures
Applications
Minimizing the risk of hitting concealed objects when drilling anchor
holes or through holes, breaking out openings and in diamond coring and
sawing work
Rebar extension (post-installed rebar connections) in structural applications
Inspection of floors, decks, slabs, balconies, etc. in structures such as tunnels, bridges and buildings
PS 1000-B X-Scan
Item #3503609
- 1x PS 1000 Scanner
- 1x Battery pack PSA 81
- 1x Torque wrench PSW 1000-3
- 5x PSA 13 reference grid
- 1x PUA 81 Mains adapter
- 1x Case
- 1x PS 1000 FCC Registration Document
- 1x PS 1000 Shipping Box
Technical Data
Accuracy of depth indication | <4 in: ±0.5 in;>4 in: ±15 % 1 |
Data memory | Aprox. 20 scans |
Data memory (scanner) | Aprox. 20 scans |
IP protection class | IP 54 (IEC 529), battery IP 56 |
Battery type | Li-ion |
Operation time with Li-ion battery | 4 h |
Operating temperature range | 5 - 122 °F |
Dimensions (scanner) | 12.5 x 7.5 x 5.6 in |
Weight (scanner) (incl. battery) | 5.4 lb. |
Max. detection range for object localization | 12 in 2 |
Disclaimer | Performance dependent on depth, spacing, size and type of object and base material type and condition |
Remark about max. detection range for object localization | Depending on base material condition (damp or dry) and object class |
1 Performance and accuracy can be significantly affected by site conditions. See operating instructions.
2 Performance and accuracy can be significantly affected by site conditions. See operating instructions.