SL Enterprises SolarSL Enterprises

Home
SLE Solar Catalog
Contact
Policies
Mission
Links

 

Search:


Home: SLE Solar Catalog: Accessories: Load Center:

Inteli-Power 4300 AC/DC Distribution Panel
Cat. No. MT-PD4300
Weight 6 lbs

 

AC/DC Distribution Panel and Inteli-Power Converter with Charge Wizard


Inteli-Power AC Features:
  • Accepts up to 7 branch circuit breakers when using split breakers.
  • AC Panel features 12 built-in push and lock strain relief wiring connectors for quick installation. Saves over 50% on installation cost.
  • Vertical or horizontal mounting choices.
  • Attractive light weight panel design made from impact-resistant high temperature polymers.
  • Note: 30 AMP main breaker and AC breakers are not included and shown for reference only.
Covered by one or more of the following patents: 5,687,066 5,600,550 5,982,643 6,184,649 6,424,520 - One or more additional patents pending.

Inteli-Power DC Features:
  • Top two fuse holders recommended for low current devices such as smoke detectors and carbon monoxide detectors.
  • 12 Branch fuse holders with maximum rating of 20 AMPS each.
  • Optional L.E.D. indicators identify which fuse is blown.
  • Converter/Charger section is accessible from the front.
  • Converter/Charger ratings of 45 and 60 AMP.
  • Easy access reverse battery protection fuses.
  • Optional DC Ground Buss can be user-installed in the DC wiring compartment.

Other PD4300 Series Features:
  • Reverse battery protection
  • Electronic current limiting
  • Low line voltage protection
  • Intelligent cooling fan
  • High voltage protection
  • Automatic thermal protection
  • Press open door for easy access to circuit breakers
  • Front access to large wiring compartment
Housing Features:
  • Snap lock cover stays shut while traveling. Opens with a touch.
  • Attractive design with fine textured finish.
  • Special formulation plastic is very durable and engineered for use in higher temperature applications.

Inteli-Power 4300 Series models can recharge the battery to 90% in 2-3 hours using our patented Charge Wizard technology.

  • The built-in Charge Wizard automatically selects one of four operating modes: BOOST, NORMAL, STORAGE, DESULFATION.
  • BOOST Mode 14.4 Volts - Rapidly brings RV battery up to 90% of full charge. In the BOOST mode the Charge Wizard status indicator stays on.
  • NORMAL Mode 13.6 Volts - Safely completes the charge. In the NORMAL mode the Charge Wizard status indicator flashes once every second.
  • STORAGE Mode 13.2 Volts - Maintains charge with minimal gassing or water loss. In the STORAGE mode the Charge Wizard status indicator flashes once every 8 seconds.
  • DESULFATION Mode 14.4 Volts every 21 hours for a period of 15 minutes to prevent battery stratification. In the DESULFATION mode the Charge Wizard status indicator stays on.


PD4300 Inteli-Power Panel Specifications Table
  PD4345 PD4360
Maximum DC Output Current 45-AMPS 60-AMPS
Maximum Continuous Input Power 725 WATTS 1,000 WATTS
No Load DC Output Voltage 13.6 VDC 13.6 VDC
No Load Voltage Tolerance +/- .3 VDC +/- .3 VDC
Full Load Output Voltage > 12.6 VDC > 12.6 VDC
Ripple and Noise Voltage <50 MV RMS <50 MV RMS
Input Voltage Tolerance 105 - 130 VAC 105 - 130 VAC
Input Voltage Frequency 50-60 HZ 50-60 HZ
Peak Inrush Current 32-AMPS 47-AMPS
Efficiency (Typical) > 80% > 80%
Reverse Battery Protection YES YES
Electronic Current Limiting YES YES
Cooling Fan Auto-variable speed Auto-variable speed
Back Up Thermal Protection YES YES
Full Function Charge Wizard YES YES
Storage Temperature 20-80C 20-80C
Operating Temperature 0-50C 0-50C
Hipot Voltage Test <-------- 1240 V @ INPUT TERMINALS -------->
Over Voltage Protection YES YES
Under Voltage Protection YES YES
Weight 10 LBS. 10 LBS.
Cutout Size 10.125W x 13.25H 10.125W x 13.25H
Dimensions 11.85W x 14.125H x 8.5D 11.85W x 14.125H x 8.5D
UL & c UL Listed YES YES
     
AC Distribution Specs:    
Rating 120 VAC/30 AMPS 120 VAC/30 AMPS
Breakers Max. 30 AMP Main... Up to 7 Branch Circuits
     
DC Distribution Specs:    
DC Fuse Positions 12/18 12/18
Blown Fuse Indicators Optional Optional
Ground Bar Optional Optional

 

*Retail and OEM Part Numbers will be determined by your selected options when you place your order.

 

 