SL Enterprises SolarSL Enterprises

Home
SLE Solar Catalog
Contact
Policies
Mission
Links

 

Search:


Home: SLE Solar Catalog: Engineered Systems: Backup/Remote Power:

FLEXware 500 Assemblies with OutBack Inverter/Chargers
Cat. No. SWI-9967150xx
Weight 300 lbs

SunWize® FLEXware Assemblies with OutBack Inverter/Chargers

SunWize, an OutBack/ETL Integrating Partner, offers pre-assembled power center assemblies listed to UL-508A. SunWize FLEXware power centers are assembled, wired and tested by SunWize in a code-compliant package. These FLEXware power centers are a modular building block for the OutBack FX and GFX series inverter/chargers allowing  modular expansion from single inverter back-up systems to a multiple inverter village power system. SunWize FLEXware power center’s versatile design allows the choice of many installed options and offer a generous number of knock-outs allowing the installation of conduit, cable glands and other installation accessories.

OutBack’s new, attractive FLEXware design also enables a lighter weight installation. The corrosion-resistant aluminum, silver powder-coated enclosures makes for a great looking installation that will last and look great for years to come. All FLEXware power centers are designed to be wall mounted for an indoor installation. The compact and flexible design of the mounting plate allows the inverters to be positioned in either a vertical or horizontal orientation for a professional-looking installation.

FLEXware 500
For applications with medium power requirements such as homes or light commercial power systems, the FLEXware 500 supports up to two OutBack inverter/chargers and two FM60 or FM80 controllers. Standard FW500 power center assemblies include all of the protective overcurrent devices, two AC bypass breakers, two AC input breakers, two AC output breakers, AC I/O bus bars, and DC main breaker(s). Also included are a 500A DC negative shunt, negative bus bar, ground bus bar, positive/negative DC bus bar, DC main  breaker bus bar, and a remote battery temperature sensor. Dual inverter assemblies include a HUB4 communications manager.

The FW500-AC section functions as a 120/240V AC load breaker subpanel with space for adding eight OB-AC DIN mount breakers. The FW500-DC section allows DC load circuit breakers by the addition of eight OB-DC panel mount breakers. Space limited when used with FM60 charge controllers and/or PV-GFP.

Size: 20.3” H x 46.3” W. Unit weight: 177 lbs.

Part # AC Power Model Description
FW500 with OutBack FX Sealed Inverter/Chargers
For stand-alone UPS or generator powered battery systems
996715070-F 2500W OBPP-FX2524T-1 One FX 2500W 24 Vdc-120 Vac 175 Adc breaker 60A bypass breaker
996715071-F 5000W OBPP-FX2524T-2 Two FX 2500W 24 Vdc-120/240 Vac 175 Adc breaker 60A bypass breaker
996715075-F 3000W OBPP-FX3048T-1 One FX 3000W 48 Vdc-120 Vac 100 Adc breaker 60A bypass breaker
996715076-F 6000W OBPP-FX3048T-2 Two FX 3000W 48 Vdc-120/240 Vac 100 Adc breaker 60A bypass breaker




FW500 with OutBack FX Inverter/Charger - 50 Hz Systems
For stand-alone, UPS or generator powered battery systems
996715084-F
2300W
OBPP-FX2348ET-1
One FX 2300W 48 Vdc-230 Vac 50 Hz, 100 Adc breaker, 30A bypass breaker
996715085-F
4600W
OBPP-FX2348ET-2
Two FX 2300W 48 Vdc-230 Vac 50 Hz, 100 Adc breaker, 30A bypass breaker
996715086-F
3000W
OBPP-VFX3048E-1
One VFX 3000W 48 Vdc-230 Vac 50 Hz, 175 Adc breaker, 30A bypass breaker




FW500 with VFX Vented Inverter/Chargers
For stand-alone, UPS and generator powered battery systems
996715031-F
2800W
OBPP-VFX2812-1
One VFX 2800W 12 Vdc-120 Vac, 250 Adc breaker, 60A bypass breaker
996715032-F
5600W
OBPP-VFX2812-2
Two VFX 2800W 12 Vdc-120/240 Vac, 250 Adc breaker, 60A bypass breaker
996715033-F 3500W OBPP-VFX3524-1
One VFX 3500W 24 Vdc-120 Vac, 250 Adc breaker, 60A bypass breaker
996715034-F 7000W OBPP-VFX3524-3
Two VFX 3500W 24 Vdc-120/240 Vac, 250 Adc breaker, 60A bypass breaker
996715035-F 3600W OBPP-VFX3648-1
One VFX 3600W 48 Vdc-120 Vac, 175 Adc breaker, 50A bypass breaker
996715036-F 7200W OBPP-VFX3648-2
Two VFX 3600W 24 Vdc-120/240 Vac, 175 Adc breaker, 60A bypass breaker




PV Grid-Tie battery back-up
FW500 with OutBack GT Sealed Inverter/charger and FW-SP-ACA surge protector
For PV Grid-Tie battery back-up (must include MX60 option – sold separately)
996715058-F
2500W
OBPP-GTFX2524-1
One GTFX 2500W 24 Vdc-120 Vac, 175 Adc breaker, 60A bypass breaker
996715059-F
5000W
OBPP-GTFX2524-2
Two GTFX 2500W 24 Vdc-120/240 Vac, 175 Adc breaker, 60A bypass breaker
996715046-F
3000W
OBPP-GTFX3048-1
One GTFX 3000W 48 Vdc-120 Vac, 100 Adc breaker, 60A bypass breaker
996715047-F 6000W OBPP-GTFX3048-2
Two GTFX 3000W 48 Vdc-120/240 Vac, 100 Adc breaker, 60A bypass breaker




FW500 with ‘GVFX’ Vented Inverter/Charger and FW-SP-ACA surge protector
For PV Grid-Tie battery back up systems (must include MX60 option – sold separately)
996715045-F
3600W
OBPP-GVFX3648-1
One GVFX 3600W 48 Vdc-120 Vac, 175 Adc breaker, 60A bypass breaker
996715044-F
7200W
OBPP-GVFX3648-2
Two GVFX 3600W 48 Vdc-120/240 Vac, 175 Adc breaker, 60A bypass breaker
996715062-F
3500W
OBPP-GVFX3524-1
One GVFX 3500W 24 Vdc-120 Vac, 250 Adc breaker, 60A bypass breaker
996715063-F 7000W OBPP-GVFX3524-2
Two GVFX 3500W 24 Vdc-120/240 Vac, 250 Adc breaker, 60A bypass breaker

Charger Options




Controller:

Model:





©SL Enterprises All rights reserved