|
Home: SLE Solar Catalog: Engineered Systems: Backup/Remote Power:
FLEXware 500 Assemblies with OutBack Inverter/Chargers Cat. No. SWI-9967150xx Weight 300 lbs | |
SunWize® FLEXware Assemblies with OutBack Inverter/Chargers
SunWize, an OutBack/ETL Integrating Partner, offers pre-assembled power
center assemblies listed to UL-508A. SunWize FLEXware power centers are
assembled, wired and tested by SunWize in a code-compliant package.
These FLEXware power centers are a modular building block for the
OutBack FX and GFX series inverter/chargers allowing modular
expansion from single inverter back-up systems to a multiple inverter
village power system. SunWize FLEXware power center’s versatile design
allows the choice of many installed options and offer a generous number
of knock-outs allowing the installation of conduit, cable glands and
other installation accessories.
OutBack’s new, attractive FLEXware design also enables a lighter weight
installation. The corrosion-resistant aluminum, silver powder-coated
enclosures makes for a great looking installation that will last and
look great for years to come. All FLEXware power centers are designed
to be wall mounted for an indoor installation. The compact and flexible
design of the mounting plate allows the inverters to be positioned in
either a vertical or horizontal orientation for a professional-looking
installation.
FLEXware 500
For applications with medium power requirements such as homes or light
commercial power systems, the FLEXware 500 supports up to two OutBack
inverter/chargers and two FM60 or FM80 controllers. Standard FW500
power center assemblies include all of the protective overcurrent
devices, two AC bypass breakers, two AC input breakers, two AC output
breakers, AC I/O bus bars, and DC main breaker(s). Also included are a
500A DC negative shunt, negative bus bar, ground bus bar,
positive/negative DC bus bar, DC main breaker bus bar, and a
remote battery temperature sensor. Dual inverter assemblies include a
HUB4 communications manager.
The FW500-AC section functions as a 120/240V AC load breaker subpanel
with space for adding eight OB-AC DIN mount breakers. The FW500-DC
section allows DC load circuit breakers by the addition of eight OB-DC
panel mount breakers. Space limited when used with FM60 charge
controllers and/or PV-GFP.
Size: 20.3” H x 46.3” W. Unit weight: 177 lbs.
Part
# |
AC Power |
Model |
Description |
FW500 with OutBack FX Sealed Inverter/Chargers
For stand-alone UPS or generator powered battery systems |
996715070-F |
2500W |
OBPP-FX2524T-1 |
One FX 2500W 24 Vdc-120 Vac 175 Adc breaker 60A bypass
breaker |
996715071-F |
5000W |
OBPP-FX2524T-2 |
Two FX 2500W 24 Vdc-120/240 Vac 175 Adc breaker 60A bypass
breaker |
996715075-F |
3000W |
OBPP-FX3048T-1 |
One FX 3000W 48 Vdc-120 Vac 100 Adc breaker 60A bypass
breaker |
996715076-F |
6000W |
OBPP-FX3048T-2 |
Two FX 3000W 48 Vdc-120/240 Vac 100 Adc breaker 60A bypass
breaker |
|
|
|
|
FW500
with OutBack FX Inverter/Charger - 50 Hz Systems
For stand-alone, UPS or generator powered battery systems |
996715084-F
|
2300W
|
OBPP-FX2348ET-1
|
One FX 2300W 48 Vdc-230 Vac 50
Hz, 100 Adc breaker, 30A bypass breaker
|
996715085-F
|
4600W
|
OBPP-FX2348ET-2
|
Two FX 2300W 48 Vdc-230 Vac 50
Hz, 100 Adc breaker, 30A bypass breaker
|
996715086-F
|
3000W
|
OBPP-VFX3048E-1
|
One VFX 3000W 48 Vdc-230 Vac 50
Hz, 175 Adc breaker, 30A bypass breaker
|
|
|
|
|
FW500
with VFX Vented Inverter/Chargers
For stand-alone, UPS and generator powered battery systems |
996715031-F
|
2800W
|
OBPP-VFX2812-1
|
One VFX 2800W 12 Vdc-120 Vac,
250 Adc breaker, 60A bypass breaker
|
996715032-F
|
5600W
|
OBPP-VFX2812-2
|
Two VFX 2800W 12 Vdc-120/240
Vac, 250 Adc breaker, 60A bypass breaker
|
996715033-F |
3500W |
OBPP-VFX3524-1
|
One VFX 3500W 24 Vdc-120 Vac,
250 Adc breaker, 60A bypass breaker
|
996715034-F |
7000W |
OBPP-VFX3524-3
|
Two VFX 3500W 24 Vdc-120/240
Vac, 250 Adc breaker, 60A bypass breaker
|
996715035-F |
3600W |
OBPP-VFX3648-1
|
One VFX 3600W 48 Vdc-120 Vac,
175 Adc breaker, 50A bypass breaker
|
996715036-F |
7200W |
OBPP-VFX3648-2
|
Two VFX 3600W 24 Vdc-120/240
Vac, 175 Adc breaker, 60A bypass breaker
|
|
|
|
|
PV
Grid-Tie battery back-up |
FW500
with OutBack GT Sealed Inverter/charger and FW-SP-ACA surge protector
For PV Grid-Tie battery back-up (must include MX60 option – sold
separately) |
996715058-F
|
2500W
|
OBPP-GTFX2524-1
|
One GTFX 2500W 24 Vdc-120 Vac,
175 Adc breaker, 60A bypass breaker
|
996715059-F
|
5000W
|
OBPP-GTFX2524-2
|
Two GTFX 2500W 24 Vdc-120/240
Vac, 175 Adc breaker, 60A bypass breaker
|
996715046-F
|
3000W
|
OBPP-GTFX3048-1
|
One GTFX 3000W 48 Vdc-120 Vac,
100 Adc breaker, 60A bypass breaker
|
996715047-F |
6000W |
OBPP-GTFX3048-2
|
Two GTFX 3000W 48 Vdc-120/240
Vac, 100 Adc breaker, 60A bypass breaker
|
|
|
|
|
FW500
with ‘GVFX’ Vented Inverter/Charger and FW-SP-ACA surge protector
For PV Grid-Tie battery back up systems (must include MX60 option –
sold separately) |
996715045-F
|
3600W
|
OBPP-GVFX3648-1
|
One GVFX 3600W 48 Vdc-120 Vac,
175 Adc breaker, 60A bypass breaker
|
996715044-F
|
7200W
|
OBPP-GVFX3648-2
|
Two GVFX 3600W 48 Vdc-120/240
Vac, 175 Adc breaker, 60A bypass breaker
|
996715062-F
|
3500W
|
OBPP-GVFX3524-1
|
One GVFX 3500W 24 Vdc-120 Vac,
250 Adc breaker, 60A bypass breaker
|
996715063-F |
7000W |
OBPP-GVFX3524-2
|
Two GVFX 3500W 24 Vdc-120/240
Vac, 250 Adc breaker, 60A bypass breaker
|
Charger Options
|
|
|